Prg V676 User Manual 3.5 Bedienungsanleitung Seite 322

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 444
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 321
304 V676
®
/ V476
®
CONTROL CONSOLE USER MANUAL
Priority
The Priority feature sets a Priority Level from 0-10.
Pile-On / Pile-Off Behavior:
+ Higher priority state overrides lower, deselect returns to lower priority state.
+ Equal priority recall replaces recall at that priority.
+ Intensity: HTP for submasters at a given priority level.
Example of Submaster Priority Interaction:
Submaster 1 is assigned to the default priority of zero with Cue 100 "wash look" selected/recalled on stage.
Submaster 2 is assigned to priority of 1 with Cue 101 "audience bally" loaded into the submaster. When Submaster 2
is selected, its contents will override Submaster 1 recalling Cue 101. When Submaster 2 is deselected, the console
will automatically
restore to Cue 100.
To set priority using command line:
+ At console keypad, press [Sub] [n] [Thru] [m] [At] p - where p is priority number 0-10.
To set priority using submaster touchscreen:
Step 1. Choose a submaster to bring up its Setup options. ("Choose" is activated by touching the specific
submaster on the touchscreen.)
Step 2. Using touchscreen, set priority level.
Step 3. Press
Closeto close Setup screen.
Priority
Seitenansicht 321
1 2 ... 317 318 319 320 321 322 323 324 325 326 327 ... 443 444

Kommentare zu diesen Handbüchern

Keine Kommentare