DMX512 REFERENCE GUIDE
110 02.3004.0300.54
6 Plate cycles full travel (75%)
along Y vector
5 Plate cycles full travel (100%)
along Y vector
4 Plate cycles full travel (25%)
along X vector
3 Plate cycles full travel (50%)
along X vector
2 Plate cycles full travel (75%)
along X vector
1 Plate cycles full travel (100%)
along X vector
0 Plate moves from X & Y EOT
to opposite X & Y EOT syn-
chronous repeatedly (100%)
008 Fixed Gobo N/A
009 Rotating Gobos 9 Cycle from wheel position 0
to position 1 CW, from posi-
tion 1 to position 0 CCW
repeatedly. Pause briefly on
position 0 and 1
8 Cycle from wheel position 0
to position 5 CCW, from posi-
tion 5 to position 0 CW
repeatedly. Pause briefly on
position 0 and 5
7 Cycle from wheel position 0
to position 3 CW, from posi-
tion 3 to position 0 CCW
repeatedly. Pause briefly on
position 0 and 3
6 Cycle from wheel position 0
to position to position 6 CCW,
from position 6 to position 0
CCW repeatedly. Pause
briefly on position 0 and 6
5 Continuous wheel position
CW to next gobo position on
wheel (from 2 to 3, 5 to 0)
Gobos on wheels do not
rotate. Pause briefly on each
gobo
4 Cycle gobos between orien-
tation 0° & 180°
3 Spin gobos CW (100%)
wheel does not move
2 Spin gobos CW (50%) wheel
does not move
Table 4-9: VL7B/VL7UB Spot Luminaire Mechanical Tests (Continued)
Test Number Test Parameter Error Codes/Comments